How Long Can a Generator Run? Fuel Calculator
The generators we rank run 5 to 18 hours on a full tank of gas, per their makers, depending on the model and the load. The Westinghouse WGen5300DFcv runs 11 hours on its 4.7 gal tank at 50% load, per the maker, so 12 hours a day for 3 days takes about 15 gallons. Pick your generator, fuel and outage below.
Westinghouse WGen5300DFcv on gasoline, 50% load
11h
On the 4.7 gal tank, per the maker
15gal
Gasoline for 36 hours: 12 h a day for 3 days
- That is 0.4 gal an hour and 5.1 gal a day, or 3.3 tank fills.
- In 5-gallon cans: 4.
- Runtime is the maker's figure at 50% load, about 2,650 W. A heavier load burns faster than this.
CDC: Only run a generator outside, more than 20 feet from any windows, doors and vents, and never inside your home or garage, even with the doors and windows open. Keep a battery-powered or battery backup CO detector in the home while it runs.
4.7 gal tank · 5,300 W running on gas · 4,800 W on propane
Runtime per tank, as each maker states it
Every figure is from the maker's spec sheet, at the load the maker names. Gallons per hour is the tank divided by the hours. A blank means the maker does not publish that figure.
| Generator | Gas tank | Gas, 25% load | Gas, 50% load | Propane |
|---|---|---|---|---|
| Westinghouse WGen5300DFcv | 4.7 gal | 14.5 h (0.3 gal/h) | 11 h (0.4 gal/h) | 9 h at 50%, tank not stated |
| Westinghouse WGen3600DFcv | 4 gal | 14 h (0.3 gal/h) | 10.5 h (0.4 gal/h) | 16.5 h at 25%, 14 h at 50% on a 20 lb tank |
| WEN DF360iX | 1.5 gal | 5 h (0.3 gal/h) | 14 h at 50% on a 20 lb tank | |
| Westinghouse iGen5000DFc | 3.4 gal | 18 h (0.2 gal/h) | 22 h at 25%, tank not stated | |
| Champion 201169 Tri-Fuel | 8.5 gal | 12 h (0.7 gal/h) | 6.5 h at 50% on a 20 lb tank | |
| DuroMax XP13000HX | 8.3 gal | 17 h (0.5 gal/h) | 8.5 h (1 gal/h) | 13 h at 25%, 6.5 h at 50%, tank not stated |
Storing the fuel you will need
- Stabilize it. Westinghouse says gasoline can deteriorate in as little as 30 days, leaving gum and varnish that can stop the engine starting, and recommends stabilizer full time. Mix it into the can before fueling, then run the generator five minutes so it reaches the whole fuel system.
- Rotate it. Champion gives stabilized ethanol-blended gasoline up to 1 year, kept cool and dry. Our suggestion: use stored cans in a car or mower and refill them well inside that year, so the gas you start an outage with is the freshest you have.
- Use the right gas. Both manuals call for unleaded with 10% ethanol or less, and never E15 or E85.
- Storing the generator. Westinghouse: under a month, no service; 2 to 6 months, fresh stabilized gas and drain the carburetor float bowl; 6 months or longer, drain the tank and the float bowl.
- Propane keeps. Champion notes that propane and natural gas do not leave the carburetor buildup stale gasoline does, which is one reason a dual-fuel model suits a generator that waits months between outages.
- Refuel cold. Engine off, then at least two minutes to cool before you open the tank, per both manuals.
Read next
- Generator Sizing Calculator
Add your loads. See running watts, surge watts and the generator class that covers them.
- Generator Maintenance Checklist: Oil, Fuel and Test Runs
A portable generator maintenance schedule from the makers' manuals: oil intervals, fuel stabilizer, monthly test runs, storage and a storm-season check.
- Propane vs Gas Generator: Is Dual Fuel Worth It?
Propane stores for years but gives about 10% fewer watts and burns more gallons; gasoline goes stale in weeks. What maker specs say about each fuel.
- How to Connect a Generator to Your House Safely
Three safe ways to connect a generator to a house: cords, an interlock or a transfer switch. What each does for you, and why you never backfeed.
- Power Station vs Generator: Which One Fits Your Outage?
Choose a power station for short outages and indoor use, and a generator for multi-day outages or a well pump. The arithmetic and the safety line.
Questions people ask
How long can a generator run on a tank of gas?
It depends on the tank and the load. Among the generators we rank, the makers' figures run from 5 hours (WEN DF360iX, 1.5 gal at 50% load) to 18 hours (Westinghouse iGen5000DFc, 3.4 gal at 25% load). A heavier load empties the tank faster.
How much gas does a generator use per hour?
Divide the tank by the maker's runtime. On our list that ranges from about 0.2 gal an hour (Westinghouse iGen5000DFc at 25% load) to about 1 (DuroMax XP13000HX at 50%). Running 12 hours a day, multiply by 12.
Does a generator run longer on propane or gasoline?
Per tank, it depends on the model. Champion states the 201169 runs 12 hours on its 8.5 gal gas tank but 6.5 hours on a 20 lb propane tank, both at 50% load. Propane also lowers the output: the makers list fewer running watts on propane for every dual-fuel model we rank.
How long does stored gasoline last?
Not long without help. Westinghouse warns that gasoline stored for as little as 30 days can deteriorate, and recommends fuel stabilizer full time. Champion puts ethanol-blended gasoline with a properly formulated stabilizer at up to 1 year, stored cool and dry.
Can I refuel a generator while it is running?
No. Westinghouse's manual says never refuel while the engine is running: turn it off and let it cool for at least two minutes first. Champion's manual says the same.
How far from the house should it run?
CDC says outside only, more than 20 feet from any windows, doors and vents, and never in your home or garage, even with the doors and windows open.
Sources for this page
- Westinghouse: WGen5300DFcv specifications
- Westinghouse: WGen3600DFcv specifications
- WEN: DF360iX product page
- Westinghouse: iGen5000DFc specifications
- Champion: 201169 Tri-Fuel specifications
- DuroMax: XP13000HX specifications
- Westinghouse: WGen3600DFcv Owner's Manual, fuel and storage (PDF)
- Champion: 201169 Tri-Fuel Operator's Manual, storage (PDF)
- CDC: Carbon Monoxide (CO) Poisoning Basics